Skip to content Skip to footer
Bağdat Caddesi, Rüzgar Gülü Çıkmazı Sokak No: 2/1 Feneryolu, Kadiköy - İstanbul

DTlite real-time PCR instrument

About DTlite real-time PCR instrument

DTlite real-time PCR instrument is used for qualitative and quantitative analysis of DNA and RNA targets. It is an optimum choice for diagnostic laboratories with small or medium throughput workflow. The device can be used for qualitative and quantitative analysis in the fields of:

• Human genetics;

• Gene Expression profiling;

• Pathogen detection, quantification and genotyping;

• Microbiome composition analysis.

The software with user-friendly interface, common to all DT real-time PCR instruments, controls the device. Original software lowers the probability of mistakes and is used for sophisticated assays requiring multiple settings application.

Advantages of DTlite:

• Tubes Height Measurement system provides “openness” of the instrument to different types of plastic (low and high profile; flat and domed caps; strips, plates).

• Simultaneous detection of a fluorescent signal in all wells of the matrix provides uniformity of detection and high speed of the instrument;

• Narrow range filters (cross-talk cut-off function);

• No “edge effect” – the thermo-block moving and positioning system ensures its movement in the horizontal and vertical positions, which guarantees complete isolation of the reaction tubes from the influence of environmental factors such as light penetration into the optical path and temperature non-uniformity between the edge rows of the matrix and its central part.

• The hot lid module provides reliable heat contact between tubes and the thermal block plate maintaining temperature of the tube caps at the level of 105±1°С in order to prevent condensate formation on the tube caps, since it may cause substantial distortions in the luminous flux measurements;

• Data protection system provides stable and safe operation of the instrument in the event of an unstable power supply. All parameters of the current run are recorded in the instrument’s own memory;

• The software has a plenty of settings allowing advanced users to obtain specific data and finely tune instrument for a given task;

• Automated filling template in case of usage DNA-Technology PCR kits;

• Can be integrated into laboratory information systems (LIS) to store data in standard graphic and text formats;

• Ability to control multiple instruments from a single control computer increases lab productivity and allows you to simultaneously conduct a wide range of PCR tests using kits with different amplification programs;

• The narrow body and compact design allow you to place several instruments in a small area.

Assay

Linear RangegE

Sample Type

Categories

HbA1c

2.8% ~ 15.5%

Blood

Diabetes

IgA

0.23   ~ 5.10g/L

Blood/Plasma/Serum

Immune   Disease

IgE*5 IU/mL ~ 1000 IU/mLPlasma/Serum

IgG

1.8 ~ 26.0 g/L

Blood/Plasma/Serum

IgM

0.18 ~ 4.60 g/L

Plasma/Serum

C3

0.19  ~ 4.70 g/L

Plasma/Serum

C4

0.06  ~ 2.20 g/L

Plasma/Serum

KAP

0.88 ~ 12.20 g/L

Serum

LAM

0.65 ~ 7.10   g/L

Serum
FLC Free KAP*5.0  ~ 200 mg/LSerum
FLC Free LAM*5.0 ~ 200 mg/LSerum

ASO

41 ~ 607 IU/mL

Serum

Rheumatoid   Disease

RF

20  ~ 306 IU/mL

Serum

CCP*

15  ~  200 IU/mL

Serum

D-Dimer

0.28 ~ 15.70mg/L

Plasma

Cardiovascular   Disease

UsCRP

0.22  ~ 19.00mg/L

Plasma/Serum

LP(a)

60 ~ 1200   mg/L

Serum

FR-CRP

0.5 ~  380.0 mg/L

Blood/plasma/Serum

Inflammation

CRP

1.6  ~ 152.0 mg/L

Plasma/Serum

SAA

3 ~ 200 mg/L

Blood/plasma/Serum

TRF

0.25 ~ 6.10 g/L

Serum

Urine   IgG

4  ~ 100 mg/L

Urine

Kidney   Disease

Urine   TRF

1 ~  80 mg/L

Urine

A1M

5  ~ 200 mg/L

Urine

mALB

9.5 ~  230.0 mg/L

Urine

CysC

0.4  ~ 7.6 mg/L

Plasma/Serum

BMG

0.4  ~ 13.0 mg/L

Plasma/Serum/Urine

Önerilen Ürünler

Kapiler Elektroforez ile Serum Proteini

Yüksek çözünürlüklü sonuçlarla yüksek verimli Serum Protein Elektroforezi.

HbA1c

Ödün Verilmemiş HbA1c Sonuçları.

Hemoglobin bozuklukları tarama

Hemoglobin bozukluklarının taranmasında yüksek çözünürlüklü yöntem.

Kapiler Elektroforez ile Serum Proteini

Yüksek çözünürlüklü sonuçlarla yüksek verimli Serum Protein Elektroforezi.

Kapiler Elektroforez ile Serum Proteini

Yüksek çözünürlüklü sonuçlarla yüksek verimli Serum Protein Elektroforezi.

Kapiler Elektroforez ile Serum Proteini

Yüksek çözünürlüklü sonuçlarla yüksek verimli Serum Protein Elektroforezi.

Parameter

DTlite

DTlite 4S1

DTlite 5S1

General characteristics

Hot lid 105°С±1°С

Adjustable height of the tubes

Autonomous operation mode (without using a control computer)

Protection against mains voltage failures (automatic restart of the amplification program)

Pre-calibration of the device

No need for additional calibrations

Warranty period (24 months)

Post-warranty service

Line voltage 100-240 W

Power consumption max 550 W

Frequency 50/60 Hz

Size 210 × 480 × 310 mm

Weight 17 kg

Thermal unit characteristics

Thermal block plate format

Aluminum matrix

Heating and cooling method with 6 Peltier thermoelectric elements

Forced cooling and heating of matrix

No «edge effect»

Number of wells in thermal block

48

48

Volume of reaction mixture (allowable), mcl

10 – 100

 

10 – 100

Volume of reaction mixture (recommended), mcl

10-50

10-50

Consumables type (separate tubes, stripes, microplates)

0,2 ml

0,2 ml

Thermal block temperature range 0-100°С

Temperature accuracy ±0,2°С

Temperature uniformity 0,6°С

Maximum heating rate of thermal unit, °С/sec

3,5

3,5

Maximum cooling rate of thermal unit, °С/sec

2,5

2,5

Average heating rate, °С/sec

3,3

3,3

Average cooling rate, °С/sec

2,1

2,1

Temperature increment (discreteness 0,1 °С)

Time increment (discreteness 0,1 sec)

General characteristics of optical system

Excitation source – LED

Number of excitation sources

4

5

Spectral range, nm

470

530

580

630

470

530

580

630

687

CCD camera

CCD matrix

Number of fluorescence measuring channels

4

5

Detection for each channel, nm

515

560

620

660

515

560

620

660

731

Simultaneous signal detection in each well

Light filters (absolute isolation of the optical channel from external light)

Eliminated cross-channel effect

Scanning time for all channels is no more than 20 sec.

“Threshold” level of fluorescence 0,05х10Е-12М

Calibrated dyes (per channel)

Fam

Hex

Rox

Су5

Fam

Hex

Rox

Су5

Су5,5

Compatibility with other fluorophores:

  • Fam – SybrGreen

  • Hex – VIC, R6G

No calibrators / need to calibrate

Dynamic range 9 lg

Melting curves analysis

Absolute and relative quantitative analysis

Software

USB-devices connection

Computer interface (USB 2.0 high speed)

Integration to LIS

Results export as .xml, .txt

Operating system: Windows® 7, Windows® 8, Windows® 10